Specific Heat Coefficient Tester
Overview
The thermal physical parameters of reservoir rock,oil and water under the heat recovery of steam injection are essential parameters in the design of thermal recovery process,the calculation of the development scheme and the study of the reservoir engineering.Therefore,a device for determining thermal physical parameters of rock,oil and water is set up to provide the necessary data parameters for reservoir description,thermal recovery numerical simulation and thermal recovery process design.
Main technical parameters
1,The resolution of the measured signal is 0.1μV;
2,Time resolution is 0.001s;
3,temperature:room temperature to 300℃;
4,pressure:0.1 to 12MPa;
5,test object:rock,crude oil,water;
6,environmental conditions:room temperature remains at 20 to 25℃;
7,power supply:AC380V,50Hz;