Simulation Device for Fracturing Fluid Rearrangement
Overview
The purpose of the device:through the indoor simulated testing research,the influence of fracturing fluid rearrangement pressure difference,rearrangement time and the viscosity of fracturing fluid after breaking glue to the reflux of proppant and rearrangement efficiency in the condition of fracturing fluid rearrangement,it can provide guidance and advice for regulation of arrangement and drainage management after actual fracturing operation.
Main technical parameters
1,working pressure:10MPa;
2,working temperature:room temperature to 100℃;
3,model specification:slit length:1200mm;
slit height:300mm;
slit width:10 to 30mm;
4,mixed fluid injection flow:9L/min;
5,filtration mode:from side;
6,high voltage windows number:seven sets;